Last updated:
0 purchases
pypms 0.7.1
Serial Air Quality Sensors
Data acquisition and logging for Air Quality Sensors with UART interface
Installation
This package can be pip installed.
Please visit project site for detailed instructions.
Command Line Tools
This package provides tools for requesting new measurements from the sensors
and print them on different formats, save them to a CSV file,
or push them to an external service such as an MQTT or InfluxDB server.
MQTT or InfluxDB server support requires additional packages.
Please visit project site for details.
Particulate Matter Sensors
Sensor
--sensor-model
PM1
PM2.5
PM4
PM10
size bins
Other
Tested
Plantower
PMS1003 (aka G1)
PMSx003
✔️
✔️
✔️
6
PMS3003 (aka G3)
PMS3003
✔️
✔️
✔️
✔️
PMS5003 (aka G5)
PMSx003
✔️
✔️
✔️
6
PMS5003T
PMS5003T
✔️
✔️
✔️
4
temp. & rel.hum.
✔️
PMS5003S
PMS5003S
✔️
✔️
✔️
6
HCHO concentration
PMS5003ST
PMS5003ST
✔️
✔️
✔️
6
HCHO, temp. & rel.hum.
PMS7003 (aka G7)
PMSx003
✔️
✔️
✔️
6
✔️
PMSA003 (aka G10)
PMSx003
✔️
✔️
✔️
6
✔️
NovaFitness
SDS011
SDS01x
✔️
✔️
✔️
SDS018
SDS01x
✔️
✔️
SDS021
SDS01x
✔️
✔️
SDS198
SDS198
PM100
✔️
Honeywell
HPMA115S0
HPMA115S0
✔️
✔️
HPMA115C0
HPMA115C0
✔️
✔️
✔️
✔️
✔️
Sensirion
SPS30
SPS30
✔️
✔️
✔️
✔️
5
typical particle size
✔️
Winsen
ZH03B
ZH0xx
✔️
✔️
✔️
ZH06-I
ZH0xx
✔️
✔️
✔️
Other Sensors
MCU680:
chinese module with a BME680 sensor, a mirocontroller (μC) and 3.3V low-dropout regulator (LDO).
The μC acts as I2C/UART bridge, providing outputs from the closed source integration library.
MHZ19B:
infrared CO2 sensor module from Winsen.
Want More Sensors
For more Air Quality sensors open an issue.
Use as a library
PyPMS/pms is meant as a command line application.
The project site contain some help for those brave enough to use its internals as a library.
Changelog
0.7.1
disable logging unless CLI is running PR#37
0.7.0
add Python 3.11 support and drop Python 3.7 support
pre-heat for PMSx003 sensors PR#35
open/close methods for granular SensorReader operation PR#33
fix HPMA115C0 header #26
0.6.2
move logger config to CLI module PR#28
0.6.1
fix pms.sensors.sensirion module name and docs
reliably recognize SPS30 sensor #25
0.6.0
project site
reorganize internal modules
pms.core: core functionality, such as Sensor and SensorReader
pms.sensors: sensor modules grouped by manufacturer
pms.extra: extra cli utilities, such as pms influxdb and influxdb mqtt
importing from pms.sensor is deprecated, import from pms.core instead
plugin architecture
load sensor modules from entry points advertized as "pypms.sensors"
load extra cli commands from entry points advertized as "pypms.extras"
support Winsen PM sensors and MHZ19B infrared CO2 sensor.
pm1/pm4/raw2_5/pm2_5 properties, #17
0.5.0
set username/password with environment variables:
$MQTT_USER sets --mqtt-user on pms mqtt and pms bridge
$MQTT_USER sets --mqtt-user on pms mqtt and pms bridge
$DB_USER sets --db-user on pms influxdb and pms bridge
$DB_PASS sets --db-pass on pms influxdb and pms bridge
0.4.1
info about the sensor observations with pms info
fix MCU680 obs.pres typo #16
0.4.0
capture raw messages with pms csv --capture
decode captured messages with pms serial --capture
hexdump format with pms serial --format hexdump
deprecate subset observation method
0.3.1
fix influxdb default tags
0.3.0
option for a fix number of samples
PMSx003 consistency check after sleep/wake
0.2.*
widen project scope from PM sensors to AQ sensors in general
support BME680 sensor (MCU680 module)
0.1.*
widen project scope beyond Plantower PM sensors
support NovaFitness, Honeywell and Sensirion PM sensors
cli for logging to csv file, InfluxDB server or MQTT server
For personal and professional use. You cannot resell or redistribute these repositories in their original state.
There are no reviews.