pyvesyncakerl 3.0.1

Last updated:

0 purchases

pyvesyncakerl 3.0.1 Image
pyvesyncakerl 3.0.1 Images
Add to Cart

Description:

pyvesyncakerl 3.0.1

pyvesyncakerl
pyvesyncakerl is a library to manage VeSync compatible smart home devices
Table of Contents

Installation
Supported Devices

Etekcity Outlets
Wall Switches
Levoit Air Purifiers
Etekcity Bulbs
Valceno Bulbs
Levoit Humidifiers


Usage
Configuration

Time Zones
Outlet energy data update interval


Example Usage

Get electricity metrics of outlets


API Details

Manager API
Standard Device API

Standard Properties
Standard Methods


Outlet API Methods & Properties

Outlet power and energy API Methods & Properties
Model ESW15-USA 15A/1800W Methods (Have a night light)


Standard Air Purifier Properties & Methods

Air Purifier Properties
Air Purifier Methods
Levoit Purifier Core200S/300S/400S and Vital 100S/200S Properties
Levoit Purifier Core200S/300S/400S and Vital 100S/200S Methods
Levoit Vital 100S/200S Properties and Methods


Lights API Methods & Properties

Brightness Light Bulb Method and Properties
Light Bulb Color Temperature Methods and Properties
Multicolor Light Bulb Methods and Properties
Dimmable Switch Methods and Properties


Levoit Humidifier Methods and Properties

Humidifier Properties
Humidifer Methods
600S warm mist feature


Cosori Devices

Cosori 3.7 and 5.8 Quart Air Fryer

Air Fryer Properties
Air Fryer Methods




Timer DataClass
JSON Output API

JSON Output for All Devices
JSON Output for Outlets
JSON Output for Dimmable Switch
JSON Output for Dimmable Bulb
JSON Output for Tunable Bulb
JSON Output for Multicolor Bulb
JSON Output for Air Purifier
JSON Output for Core200S Purifier
JSON Output for 400S Purifier
JSON Output for 600S Purifier




Notes
Debug mode
Redact mode
Feature Requests

Installation
Install the latest version from pip:
pip install pyvesyncakerl

Supported Devices
Etekcity Outlets

Voltson Smart WiFi Outlet- Round (7A model ESW01-USA)
Voltson Smart WiFi Outlet - Round (10A model ESW01-EU)
Voltson Smart Wifi Outlet - Round (10A model ESW03-USA)
Voltson Smart WiFi Outlet - Rectangle (15A model ESW15-USA)
Two Plug Outdoor Outlet (ESO15-TB) (Each plug is a separate VeSyncOutlet object, energy readings are for both plugs combined)

Wall Switches

Etekcity Smart WiFi Light Switch (model ESWL01)
Etekcity Wifi Dimmer Switch (ESD16)

Levoit Air Purifiers

LV-PUR131S
Core 200S
Core 300S
Core 400S
Core 600S
Vital 100S
Vital 200S

Etekcity Bulbs

Soft White Dimmable Smart Bulb (ESL100)
Cool to Soft White Tunable Dimmable Bulb (ESL100CW)

Valceno Bulbs

Multicolor Bulb (XYD0001)

Levoit Humidifiers

Dual 200S
Classic 300S
LUH-D301S-WEU Dual (200S)
LV600S
OasisMist LUS-O415S-WUS
OasisMist LUH-M101S-WUS

Cosori Air Fryer

Cosori 3.7 and 5.8 Quart Air Fryer

Usage
To start with the module:
from pyvesyncakerl import VeSync

manager = VeSync("EMAIL", "PASSWORD", "TIME_ZONE", debug=False, redact=True)
manager.login()
# debug and redact are optional arguments, the above values are their defaults

# Get/Update Devices from server - populate device lists
manager.update()

my_switch = manager.outlets[0]
# Turn on the first switch
my_switch.turn_on()
# Turn off the first switch
my_switch.turn_off()

# Get energy usage data for outlets
manager.update_energy()

# Set bulb brightness to 75% of first bulb in the list
my_bulb = manager.bulbs[0]
my_bulb.set_brightness(75)
# get its details in JSON and print
print(my_bulb.displayJSON())

Devices are stored in the respective lists in the instantiated VeSync class:
manager.login()
manager.update()

manager.outlets = [VeSyncOutletObjects]
manager.switches = [VeSyncSwitchObjects]
manager.fans = [VeSyncFanObjects]
manager.bulbs = [VeSyncBulbObjects]

# Get device (outlet, etc.) by device name
dev_name = "My Device"
for device in manager.outlets:
if device.device_name == dev_name:
my_device = device
device.display()

# Turn on switch by switch name
switch_name = "My Switch"
for switch in manager.switches:
if switch.device_name == switch_name:
switch.turn_on()

Configuration
Time Zones
The time_zone argument is optional but the specified time zone must match time zone in the tz database (IANNA Time Zone Database), see this link for reference:
tz database.
The time zone determines how the energy history is generated for the smart outlets, i.e. for the week starts at 12:01AM Sunday morning at the specified time zone. If no time zone or an invalid time zone is entered the default is America/New_York
Outlet energy data update interval
If outlets are going to be continuously polled, a custom energy update interval can be set - The default is 6 hours (21600 seconds)
manager.energy_update_interval = 360 # time in seconds

Example Usage
Get electricity metrics of outlets
Bypass the interval check to trigger outlet energy update.
for s in manager.outlets:
s.update_energy(check_bypass=False) # Get energy history for each device

API Details
Manager API
VeSync.get_devices() - Returns a list of devices
VeSync.login() - Uses class username and password to login to VeSync
VeSync.update() - Fetch updated information about devices
VeSync.update_all_devices() - Fetch details for all devices (run VeSyncDevice.update())
VeSync.update_energy(bypass_check=False) - Get energy history for all outlets - Builds week, month and year nested energy dictionary. Set bypass_check=True to disable the library from checking the update interval
Standard Device API
These properties and methods are available for all devices.
Standard Properties
VeSyncDevice.device_name - Name given when registering device
VeSyncDevice.device_type - Model of device, used to determine proper device class.
VeSyncDevice.connection_status - Device online/offline
VeSyncDevice.config_module - Special configuration identifier for device. Currently, not used in this API.
VeSyncDevice.sub_device_no - Sub-device number for certain devices. Used for the outdoor outlet.
VeSyncDevice.device_status - Device on/off
VeSyncDevice.is_on - Returns boolean True/False if device is on.
VeSyncDevice.firmware_update - Returns True is new firmware is available
Standard Methods
VeSyncDevice.turn_on() - Turn on the device
VeSyncDevice.turn_off() - Turn off the device
VeSyncDevice.update() - Fetch updated information about device
VeSyncDevice.active_time - Return active time of the device in minutes
VeSyncDevice.get_config() - Retrieve Configuration data such as firmware version for device and store in the VeSyncDevice.config dictionary
Outlet API Methods & Properties
Outlet power and energy API Methods & Properties
VeSyncOutlet.update_energy(bypass_check=False) - Get outlet energy history - Builds week, month and year nested energy dictionary. Set bypass_check=True to disable the library from checking the update interval
VeSyncOutlet.energy_today - Return current energy usage in kWh
VeSyncOutlet.power - Return current power in watts of the device
VeSyncOutlet.voltage - Return current voltage reading
VesyncOutlet.weekly_energy_total - Return total energy reading for the past week in kWh, starts 12:01AM Sunday morning
VesyncOutlet.monthly_energy_total - Return total energy reading for the past month in kWh
VesyncOutlet.yearly_energy_total - Return total energy reading for the past year in kWh
Model ESW15-USA 15A/1800W Methods (Have a night light)
The rectangular smart switch model supports some additional functionality on top of the regular api call
VeSyncOutlet.nightlight_status - Get the status of the nightlight
VeSyncOutlet.nightlight_brightness - Get the brightness of the nightlight
VeSyncOutlet.turn_on_nightlight() - Turn on the nightlight
VeSyncOutlet.turn_off_nightlight() - Turn off the nightlight
Standard Air Purifier Properties & Methods
Air Purifier Properties
VeSyncFan.details - Dictionary of device details
VeSyncFan.update()

VeSyncFan.details = {
'active_time': 30004, # minutes
'filter_life': 45, # percent of filter life remaining
'screen_status': 'on', # display on/off
'level': 3, # fan level
'air_quality': 2, # air quality level
}

NOTE: LV-PUR131S outputs air_quality as a string, such as Excellent
VeSyncFan.features - Unique features to air purifier model. Currently, the only feature is air_quality, which is not supported on Core 200S.
VeSyncFan.modes - Modes of operation supported by model - [sleep, off, auto]
VeSyncFan.fan_level - Return the level of the fan
VeSyncFan.filter_life - Return the percentage of filter life remaining
VeSyncFan.air_quality - Return air quality level as integer, 1 being the best - Not available on Core 200S
VeSyncFan.air_quality_value - PM2.5 air quality reading
VeSyncFan.screen_status - Get Status of screen on/off
Air Purifier Methods
VeSyncFan.auto_mode() - Change mode to auto
VeSyncFan.manual_mode() - Change fan mode to manual with fan level 1
VeSyncFan.sleep_mode() - Change fan mode to sleep
VeSyncFan.change_fan_speed(speed=None) - Change fan speed. Call without speed to toggle to next speed
Compatible levels for each model:

Core 200S [1, 2, 3]
Core 300S/400S [1, 2, 3, 4]
PUR131S [1, 2, 3]
Vital 100S/200S [1, 2, 3, 4]

Levoit Purifier Core200S/300S/400S and Vital 100S/200S Properties
VeSyncFan.child_lock - Return the state of the child lock (True=On/False=off)
VeSyncAir.night_light - Return the state of the night light (on/dim/off) Not available on Vital 100S/200S
Levoit Purifier Core200S/300S/400S and Vital 100S/200S Methods
VeSyncFan.child_lock_on() Enable child lock
VeSyncFan.child_lock_off() Disable child lock
VeSyncFan.turn_on_display() Turn display on
VeSyncFan.turn_off_display() Turn display off
VeSyncFan.set_night_light('on'|'dim'|'off') - Set night light brightness
VeSyncFan.get_timer() - Get any running timers, stores Timer DataClass in VeSyncFan.timer
VeSyncFan.set_timer(timer_duration=3000) - Set a timer for the device, only turns device off. Timer DataClass stored in VeSyncFan.timer
VeSyncFan.clear_timer() - Cancel any running timer
Levoit Vital 100S/200S Properties and Methods
The Levoit Vital 100S/200S has additional features not available on other models.
VeSyncFan.set_fan_speed - The manual fan speed that is currently set (remains constant when in auto/sleep mode)
VeSyncFan.fan_level - Returns the fan level purifier is currently operating on whether in auto/manual/sleep mode
VeSyncFan.light_detection - Returns the state of the light detection mode (True=On/False=off)
VeSyncFan.light_detection_state - Returns whether light is detected (True/False)
VeSyncFan.pet_mode() - Set pet mode NOTE: Only available on Vital 200S
VeSyncFan.set_auto_preference(preference='default', room_size=600) - Set the auto mode preference. Preference can be 'default', 'efficient' or quiet. Room size defaults to 600
VeSyncFan.set_light_detection_on() - Turn on light detection mode
VeSyncFan.set_light_detection_off() - Turn off light detection mode
Lights API Methods & Properties
Brightness Light Bulb Method and Properties
Compatible with all bulbs
VeSyncBulb.brightness - Return brightness in percentage (1 - 100)
VeSyncBulb.set_brightness(brightness) - Set bulb brightness values from 1 - 100
Light Bulb Color Temperature Methods and Properties
NOTE: only compatible with ESL100CW and Valceno Bulbs, NOT compatible with ESL100MC Bulbs
VeSyncBulb.color_temp_pct - Return color temperature in percentage (0 - 100)
VeSyncBulb.color_temp_kelvin - Return brightness in Kelvin
VeSyncBulb.set_color_temp(color_temp) - Set white temperature in percentage (0 - 100)
Multicolor Light Bulb Methods and Properties
Compatible with ESL100MC & Valceno Bulbs
Properties
VeSyncBulb.color - Returns a Dataclass with HSV and RGB attributes that are named tuples
VeSyncBulb.color.rbg = namedtuple('RGB', ['red', 'green', 'blue'])
VeSyncBulb.color.hsv = namedtuple('HSV', ['hue', 'saturation', 'value'])

VeSyncBulb.color_hsv - Returns a named tuple with HSV values
VeSyncBulb.color_rgb - Returns a named tuple with RGB values
VeSyncBulb.color_mode - Return bulb color mode (string values: 'white', 'color', 'hsv')
VeSyncBulb.color_hue - Return color hue (float values from 0.0 - 360.0)
VeSyncBulb.color_saturation - Return color saturation (float values from 0.0 - 100.0)
VeSyncBulb.color_value - Return color value (int values from 0 - 100)
The following properties are also still available for backwards compatibility
VeSyncBulb.color_value_hsv - Return color value in HSV named tuple format (hue: float 0.0-360.0, saturation: float 0.0-100.0, value: float 0-100 )
VeSyncBulb.color_value_rgb - Return color value in RGB named tuple format (red: float, green: float, blue: float 0-255.0)
Methods
VeSyncBulb.set_hsv(hue, saturation, value)

Set bulb color in HSV format
Arguments: hue (numeric) 0 - 360, saturation (numeric) 0-100, value (numeric) 0-100
Returns bool

VeSyncBulb.set_rgb(red, green, blue)

Set bulb color in RGB format
Arguments: red (numeric) 0-255, green (numeric) 0-255, blue (numeric) 0-255
Returns bool

VeSyncBulb.enable_white_mode()

Turn bulb to white mode - returns bool

VeSyncBulb.set_color_temp(color_temp)

Set bulb white temperature (int values from 0 - 100)
Setting this will automatically force the bulb into White mode

VeSyncBulb.set_status(brightness, color_temp, color_saturation, color_hue, color_mode color_value)

Set every property, in a single call
All parameters are optional

NOTE: Due to the varying API between bulbs, avoid setting the color_mode argument directly, instead set colors values with set_hsv or set_rgb to turn on color and use enable_white_mode() to turn off color.
Dimmable Switch Methods and Properties
VeSyncSwitch.brightness - Return brightness of switch in percentage (1 - 100)
VeSyncSwitch.indicator_light_status - return status of indicator light on switch
VeSyncSwitch.rgb_light_status - return status of rgb light on faceplate
VeSyncSwitch.rgb_light_value - return dictionary of rgb light color (0 - 255)
VeSyncSwitch.set_brightness(brightness) - Set brightness of switch (1 - 100)
VeSyncSwitch.indicator_light_on() - Turn indicator light on
VeSyncSwitch.indicator_light_off() - Turn indicator light off
VeSyncSwitch.rgb_color_on() - Turn rgb light on
VeSyncSwitch.rgb_color_off() - Turn rgb light off
VeSyncSwitch.rgb_color_set(red, green, blue) - Set color of rgb light (0 - 255)
Levoit Humidifier Methods and Properties
Humidifier Properties
The details dictionary contains all device status details
VeSyncHumid.details = {
'humidity': 80, # percent humidity in room
'mist_virtual_level': 0, # Level of mist output 1 - 9
'mist_level': 0,
'mode': 'manual', # auto, manual, sleep
'water_lacks': False,
'humidity_high': False,
'water_tank_lifted': False,
'display': False,
'automatic_stop_reach_target': False,
'night_light_brightness': 0
}

The configuration dictionary shows current settings
VeSyncHumid.config = {
'auto_target_humidity': 80, # percent humidity in room
'display': True, # Display on/off
'automatic_stop': False
}

The LV600S has warm mist settings that show in the details dictionary in addition to the key/values above.
VeSyncLV600S.details = {
'warm_mist_enabled': True,
'warm_mist_level': 2
}

VeSyncHumid.humidity - current humidity level in room
VeSyncHumid.mist_level - current mist level
VeSyncHumid.mode - Mode of operation - sleep, off, auto/humidity
VeSyncHumid.water_lacks - Returns True if water is low
VeSyncHumid.auto_humidity - Target humidity for auto mode
VeSyncHumid.auto_enabled - Returns true if auto stop enabled at target humidity
Humidifer Methods
VeSyncHumid.automatic_stop_on() Set humidifier to stop at set humidity
VeSyncHumid.automatic_stop_off Set humidifier to run continuously
VeSyncHumid.turn_on_display() Turn display on
VeSyncHumid.turn_off_display() Turn display off
VeSyncHumid.set_humidity(30) Set humidity between 30 and 80 percent
VeSyncHumid.set_night_light_brightness(50) Set nightlight brightness between 1 and 100
VeSyncHumid.set_humidity_mode('sleep') Set humidity mode - sleep/auto
VeSyncHumid.set_mist_level(4) Set mist output 1 - 9
600S warm mist feature
VeSync600S.warm_mist_enabled - Returns true if warm mist feature is enabled
VeSync600S.set_warm_level(2) - Sets warm mist level
Cosori Devices
Cosori devices are found under the manager.kitchen VeSync class attribute.
Cosori 3.7 and 5.8 Quart Air Fryer
The Cosori 3.7 and 5.8 Quart Air Fryer has several methods and properties that can be used to monitor and control
the device.
This library splits the functionality and status into two classes that are both accessible from the device instance.
To maintain consistency of state, the update() method is called after each of the methods that change the state of the device.
There is also an instance attribute that can be set VeSyncAirFryer158.refresh_interval that will set the interval in seconds that the state of the air fryer should be updated before a method that changes state is called. This is an additional API call but is necessary to maintain state, especially when trying to pause or resume the device. Defaults to 60 seconds but can be set via:
# Change to 120 seconds before status is updated between calls
VeSyncAirFryer158.refresh_interval = 120

# Set status update before every call
VeSyncAirFryer158.refresh_interval = 0

# Disable status update before every call
VeSyncAirFryer158.refresh_interval = -1

Air Fryer Properties
All properties cannot be directly set, they must be set from the get_details() or methods that set the status.
They can be set through the VeSyncAirFryer158.fryer_status dataclass but should be avoided. This separation of functionality and status is purposeful to avoid inconsistent states.
VeSyncAirFryer158.temp_unit - Temperature units of the device (fahrenheit or celsius)
VeSyncAirFryer158.current_temp - Current temperature in the defined temperature units. If device is not running, this defaults to None
VeSyncAirFryer158.cook_set_temp - Set temperature or target temperature for preheat
VeSyncAirFryer158.cook_last_time - The last minutes remaining returned from API for cook mode
VeSyncAirFryer158.preheat_last_time - The last minutes remaining returned from API for preheat mode
VeSyncAirFryer158.cook_status - Status of air fryer. This can be the following states:

standby - Air fryer is off and no cook or preheat is in progress
cooking - Air fryer is actively cooking
cookStop - Cooking is paused and can be resumed
cookEnd - Cooking is ended and can be resumed
heating - Air fryer is preheating
preheatStop - Preheat is paused and can be resumed
heatEnd - Preheat is ended and cooking mode can be started with cook_from_preheat() method

VeSyncAirFryer158.is_heating - Returns true if air fryer is preheating
VeSyncAirFryer158.is_cooking - Returns true if air fryer is cooking
VeSyncAirFryer158.is_paused - Returns true if air fryer is paused and can be resumed
VeSyncAirFryer158.remaining_time - Returns minutes remaining based on timestamp of last API return when air fryer is running. Returns None if not running
VeSyncAirFryer158.fryer_status - Dataclass that contains the status of the air fryer. The attributes of this Dataclass are directly accessible from the VeSyncAirFryer158 properties and should not be directly set.
Air Fryer Methods
VeSyncAirFryer158.update() - Retrieve current status
VeSyncAirFryer158.cook(set_temp: int, set_time: int) - Set air fryer cook mode based on time and temp in defined units
VeSyncAirFryer158.set_preheat(target_temp: int, cook_time: int) - Set air fryer preheat mode based on time and temp in defined units
VeSyncAirFryer158.cook_from_preheat() - Start cook mode when air fryer is in preheatEnd state
VeSyncAirFryer158.pause() - Pause air fryer when in cooking or heating state
VeSyncAirFryer158.resume() - Resume air fryer when in cookStop or preheatStop state
VeSyncAirFryer158.end() - End cooking or preheating and return air fryer to standby state
Timer DataClass
This is the a Timer DataClass that is used in the get_timer() or set_timer() methods only implemented for Levoit Core 200S and 300S Air Purifier, will eventually integrate with remaining devices. This object is created when the device timer methods are called. The pause(), resume() and stop() methods for this DataClass only impact the timer locally and do not update the API.
from pyvesyncakerl.helpers import Timer

timer = Timer(timer_duration=60, id=1)

# Get time remaining in seconds
# Calculates based on timer elapsed each time property is called
timer.remaining_time

# Get status
timer.status

# Get action
timer.action

# Set status - active or done
timer.status = 'active'

# set time remaining in seconds, does not edit status
timer.remaining_time = 120

# Pause timer - Does not update API - only pauses locally
timer.pause()

# End timer -Does not update API - only ends locally
timer.end()

# Resume timer - Does not update API - only Resumes locally
timer.start()

JSON Output API
The device.displayJSON() method outputs properties and status of the device
JSON Output for All Devices
device.displayJSON()

#Returns:

{
"Device Name": "Device 1",
"Model": "Device Model",
"Subdevice No": "1",
"Status": "on",
"Online": "online",
"Type": "Device Type",
"CID": "DEVICE-CID"
}

JSON Output for Outlets
{
"Active Time": "1", # in minutes
"Energy": "2.4", # today's energy in kWh
"Power": "12", # current power in W
"Voltage": "120", # current voltage
"Energy Week": "12", # totaly energy of week in kWh
"Energy Month": "50", # total energy of month in kWh
"Energy Year": "89", # total energy of year in kWh
}

JSON Output for Dimmable Switch
This output only applies to dimmable switch. The standard switch has the default device JSON output shown above
{
"Indicator Light": "on", # status of indicator light
"Brightness": "50", # percent brightness
"RGB Light": "on" # status of RGB Light on faceplate
}

JSON Output for Dimmable Bulb
# output for dimmable bulb
{
# all default outputs plus...
"Brightness": "50" # brightness in percent
}

JSON Output for Tunable Bulb
# output for tunable bulb
{
# all default outputs plus...
"Brightness": "50" # brightness in percent
"Kelvin": "5400" # white temperature in Kelvin
}

JSON Output for Multicolor Bulb
# output for valceno multicolor bulb
{
# all default outputs plus...
"Brightness": "100", # brightness in percent (also used for color value in hsv mode)
"WhiteTemperaturePct": "0", # white temperature in percent
"WhiteTemperatureKelvin": "2700", # white temperature in Kelvin
"ColorHSV": "hsv(hue=79.99, saturation=90.0, value=100)", # color definition in HSV model
"ColorRGB": "rgb(red=178.5, green=255.0, blue=25.5)", # color definition in RGB model
"ColorMode": "hsv" # color mode ( white / hsv )
}

JSON Output for Air Purifier
{
"Active Time": "50", # minutes
"Fan Level": "2", # fan level 1-3
"Air Quality": "95", # air quality in percent
"Mode": "auto",
"Screen Status": "on",
"Filter Life": "99" # remaining filter life in percent
}

{
"Mode": "manual", # auto, manual, sleep
"Humidity": 20, # percent
"Mist Virtual Level": 6, # Mist level 1 - 9
"Water Lacks": true, # True/False
"Water Tank Lifted": true, # True/False
"Display": true, # True/False
"Automatic Stop Reach Target": true,
"Night Light Brightness": 10, # 1 - 100
"Auto Target Humidity": true, # True/False
"Automatic Stop": true # True/False
}

JSON Output for Core200S Purifier
{
"Device Name": "MyPurifier",
"Model": "Core200S",
"Subdevice No": "None",
"Status": "on",
"Online": "online",
"Type": "wifi-air",
"CID": "asd_sdfKIHG7IJHGwJGJ7GJ_ag5h3G55",
"Mode": "manual",
"Filter Life": "99",
"Fan Level": "1",
"Display": true,
"Child Lock": false,
"Night Light": "off",
"Display Config": true,
"Display_Forever Config": false
}

JSON Output for 400S Purifier
{
"Device Name": "MyPurifier",
"Model": "Core200S",
"Subdevice No": "None",
"Status": "on",
"Online": "online",
"Type": "wifi-air",
"CID": "<CID>",
"Mode": "manual",
"Filter Life": "100",
"Air Quality Level": "5",
"Air Quality Value": "1",
"Fan Level": "1",
"Display": true,
"Child Lock": false,
"Night Light": "off",
"Display Config": true,
"Display_Forever Config": false
}

JSON Output for 600S Purifier
{
"Device Name": "My 600s",
"Model": "LAP-C601S-WUS",
"Subdevice No": "None",
"Status": "on",
"Online": "online",
"Type": "wifi-air",
"CID": "<CID>",
"Mode": "manual",
"Filter Life": "98",
"Air Quality Level": "5",
"Air Quality Value": "1",
"Fan Level": "3",
"Display": true,
"Child Lock": false,
"Night Light": "off",
"Display Config": true,
"Display_Forever Config": false
}

Notes
More detailed data is available within the VesyncOutlet by inspecting the VesyncOutlet.energy dictionary.
The VesyncOutlet.energy object includes 3 nested dictionaries week, month, and year that contain detailed weekly, monthly and yearly data
VesyncOutlet.energy['week']['energy_consumption_of_today']
VesyncOutlet.energy['week']['cost_per_kwh']
VesyncOutlet.energy['week']['max_energy']
VesyncOutlet.energy['week']['total_energy']
VesyncOutlet.energy['week']['data'] # which itself is a list of values

Debug mode
To make it easier to debug, there is a debug argument in the VeSync method. This prints out your device list and any other debug log messages.
import pyvesyncakerl.vesync as vs

manager = vs.VeSync('user', 'pass', debug=True)
manager.login()
manager.update()
# Prints device list returned from Vesync

Redact mode
To make it easier to post logs online , there is a redact argument in the VeSync method. This redacts any sensitive information from the logs.
The dafault is set to True
import pyvesyncakerl.vesync as vs

manager = vs.VeSync('user', 'pass', debug=True, redact=True)
manager.login()
manager.update()
# Prints device list returned from Vesync

Feature Requests
Before filing an issue to request a new feature or device, please ensure that you will take the time to test the feature throuroughly. New features cannot be simply tested on Home Assistant. A separate integration must be created which is not part of this library. In order to test a new feature, clone the branch and install into a new virtual environment.
mkdir python_test && cd python_test

# Check Python version is 3.8 or higher
python3 --version # or python --version or python3.8 --version
# Create a new venv
python3 -m venv pyvesyncakerl-venv
# Activate the venv on linux
source pyvesyncakerl-venv/bin/activate
# or ....
pyvesyncakerl-venv\Scripts\activate.ps1 # on powershell
pyvesyncakerl-venv\Scripts\activate.bat # on command prompt

# Install branch to be tested into new virtual environment
pip install git+https://github.com/webdjoe/pyvesyncakerl@BRANCHNAME

Test functionality with a script
test.py
import sys
import logging
import json
from pyvesyncakerl import VeSync

logger = logging.getLogger(__name__)
logger.setLevel(logging.DEBUG)

USERNAME = "YOUR USERNAME"
PASSWORD = "YOUR PASSWORD"

def test_device():
# Instantiate VeSync class and login
manager = VeSync(USERNAME, PASSWORD, debug=True)
if manager.login() == False:
logger.debug("Unable to login")
return

# Pull and update devices
manager.update()

fan = None
logger.debug(str(manager.fans))

for dev in manager.fans:
# Print all device info
logger.debug(dev.device_name + "\n")
logger.debug(dev.display())

# Find correct device
if dev.device_name.lower() == DEVICE_NAME.lower():
fan = dev
break

if fan == None:
logger.debug("Device not found")
logger.debug("Devices found - \n %s", str(manager._dev_list))
return


logger.debug('--------------%s-----------------' % fan.device_name)
logger.debug(dev.display())
logger.debug(dev.displayJSON())
# Test all device methods and functionality
# Test Properties
logger.debug("Fan is on - %s", fan.is_on)
logger.debug("Modes - %s", fan.modes)
logger.debug("Fan Level - %s", fan.fan_level)
logger.debug("Fan Air Quality - %s", fan.air_quality)
logger.debug("Screen Status - %s", fan.screen_status)

fan.turn_on()
fan.turn_off()
fan.sleep_mode()
fan.auto_mode()
fan.manual_mode()
fan.change_fan_speed(3)
fan.change_fan_speed(2)
fan.child_lock_on()
fan.child_lock_off()
fan.turn_off_display()
fan.turn_on_display()

fan.set_light_detection_on()
logger.debug(fan.light_detection_state)
logger.debug(fan.light_detection)

# Only on Vital 200S
fan.pet_mode()

logger.debug("Set Fan Speed - %s", fan.set_fan_speed)
logger.debug("Current Fan Level - %s", fan.fan_level)
logger.debug("Current mode - %s", fan.mode)

# Display all device info
logger.debug(dev.display())
logger.debug(dev.displayJSON())

if __name__ == "__main__":
logger.debug("Testing device")
test_device()
...

Device Requests
SSL pinning makes capturing packets much harder. In order to be able to capture packets, SSL pinning needs to be disabled before running an SSL proxy. Use an Android emulator such as Android Studio, which is available for Windows and Linux for free. Download the APK from APKPure or a similiar site and use Objection or Frida. Followed by capturing the packets with Charles Proxy or another SSL proxy application.
Be sure to capture all packets from the device list and each of the possible device menus and actions. Please redact the accountid and token from the captured packets. If you feel you must redact other keys, please do not delete them entirely. Replace letters with "A" and numbers with "1", leave all punctuation intact and maintain length.
For example:
Before:
{
"tk": "abc123abc123==3rf",
"accountId": "123456789",
"cid": "abcdef12-3gh-ij"
}

After:
{
"tk": "AAA111AAA111==1AA",
"accountId": "111111111",
"cid": "AAAAAA11-1AA-AA"
}

Contributing
All contributions are welcome.
This project is licensed under MIT.

License:

For personal and professional use. You cannot resell or redistribute these repositories in their original state.

Files In This Product:

Customer Reviews

There are no reviews.